Type: Ventilator
Ventilation Mode: Ippv, Sippv, Simv, Peep, Manual, Sigh (Imv, Vcv
Power: AC /DC
Source: Nitrous Oxide
Sigh Inspiratory Time: 1.5 Times
LCD Display: with LCD Display
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
H-100C
Anesthesia
Closed Circuit
Kind
Surgical
Oxygen Concentration
21%-100%
Tidal Volume
20~2000ml
Simv Rate
1~20bpm
Certification
CE, ISO13485
Group
Adult, Pediatric, Neonatal
Pressure Range
1.0~6.0 Kpa
Low Limit Setting Range
0.2~5.0 Kpa
Display
10.4"Color LCD Display
Transport Package
Wooden Case
Specification
ISO, CE
Trademark
Poweam
Origin
China
HS Code
90189070
Production Capacity
1000PCS/Month

Product Description

vENTILATOR 
10.4" LCD Display,
Parameters for ventilation monitoring: ventilation volume, tidal volume, SIMV rate, IPPV rate.
total respiratory rate, peak pressure of airway, I/E, flow rate - time waveform
Display 10.4" LCD display
Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH (IMV, VCV, PCV) 
Tidal volume 20~2000ml
Rate 1~99bpm
SIMV rate 1~20bpm
I:E 2:1~1:8
Inspiratory trigger pressure  -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressure range  1.0~6.0 kPa
SIGH inspiratory time 1.5 times
Parameters for ventilation monitoring Ventilation volume, tidal volume, SIMV rate, IPPV rate,
 total respiratory rate, peak pressure of airway, I/E, 
flow rate - time waveform, pressure - time waveform, 
inspiratory trigger pressure ,PEEP, Inspiratory platform
Oxygen Concentration 21%-100%
Oxygen Concentration alarm upper limit setting range 21%~100%
low limit setting range   10%~80%
Airway pressure alarm upper limit setting range 0.3~6.0 kPa
low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustained high-pressure alarm > 2.5 kPa
Suffocation alarm no tidal volume input for 15 seconds
Power alarm Yes
Power AC /DC
CO2, ECG  monitoring function optional