• Hospital 7′ Color LCD Display Aed Automated External Defibrillator (D-2000A)
  • Hospital 7′ Color LCD Display Aed Automated External Defibrillator (D-2000A)
  • Hospital 7′ Color LCD Display Aed Automated External Defibrillator (D-2000A)

Hospital 7′ Color LCD Display Aed Automated External Defibrillator (D-2000A)

Type: Defibrillator
Kind: Body
Certification: CE, ISO13485
Group: All
LCD Display: With LCD Display
Size: 23*25*35cm
Customization:

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
D-2000A
Gw
5kg
Display
7 Inch LCD
Transport Package
1 PCS/Carton
Specification
ISO. CE
Trademark
Poweam
Origin
China
HS Code
90189090
Production Capacity
5000PCS/Year

Product Description

(1)Defibrillator type: Manual, Synchronized, Asynchronized 
(2)Energy accuracy: < 1% 
(3)Energy selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
(4)Charging time: Maximum 10 seconds to 360 Joules
(5)Standard Adult/Pediatric Paddles  Reusable external adult paddles (pediatric paddles integrated)  

7" color LCD display
Monophasic defibrillator / monitor
ECG
ECG lead: I, II, III,, a VR, a VL, a VF, V1-V6
S-T segment analysis: -2.0-2.0mv
Protection: withstand 4000v AV/50HZ voltage in isolation and work against lectrosurgical 
interence and defibrillation.
ECG lead/cable: general lead/cable for adult, pediatric and neonatal patients
Respiration
Measurement method: Thoracic impedance <o:p>
NIBP:
Method: automatic oscillation
Working mode: manual/automatic
Measur: adult: 10-250mmHg
Ement: pediatric: 10-200mmHg
Rabge: neonatal: 10-135mmHg
TEMP:
Measurement range: 20-45ºC
Resolution: 0.1ºC
SpO2:
Display: SpO2 value, pulse histogram, waveform, pulse
Range: 0-99% for adult, pediatric and neonatal patients
Probe: stand: adult finger clip Optional: pediatric Y-type clip and neonatal wrap<o:p>
Pulse:
Pulse range: 0-300bpm
Pulse accuracy: ±2bpm

 
ECG  
ECG lead  I, II, III,, a VR, a VL, a VF, V1-V6
S-T segment analysis  -2.0-2.0mv
Protection  withstand 4000v AV/50HZ voltage in isolation and work against lectrosurgical 
interence and defibrillation.
ECG lead/cable  general lead/cable for adult, pediatric and neonatal patients 
Respiration  
Measurement method  Thoracic impedance
NIBP  
Method  automatic oscillation
Working mode  manual/automatic
Measur  Adult 10-250mmHg
Ement  Pediatric 10-200mmHg
Rabge  Neonatal 10-135mmHg
TEMP  
Measurement range  20-45ºC
Resolution  0.1ºC
SpO2  
Display  SpO2 value, pulse histogram, waveform, pulse
Range  0-99% for adult, pediatric and neonatal patients
Probe  stand adult finger clip Optional pediatric Y-type clip and neonatal wrap
Pulse  
Pulse range  0-300bpm
Pulse accuracy  ±2bpm
Hospital 7&prime; Color LCD Display Aed Automated External Defibrillator (D-2000A) Hospital 7&prime; Color LCD Display Aed Automated External Defibrillator (D-2000A) Hospital 7&prime; Color LCD Display Aed Automated External Defibrillator (D-2000A) Hospital 7&prime; Color LCD Display Aed Automated External Defibrillator (D-2000A)