• Why6280 (60 tests) 3 Parts Automatic Hematology Analyzer
  • Why6280 (60 tests) 3 Parts Automatic Hematology Analyzer
  • Why6280 (60 tests) 3 Parts Automatic Hematology Analyzer
  • Why6280 (60 tests) 3 Parts Automatic Hematology Analyzer
  • Why6280 (60 tests) 3 Parts Automatic Hematology Analyzer
  • Why6280 (60 tests) 3 Parts Automatic Hematology Analyzer

Why6280 (60 tests) 3 Parts Automatic Hematology Analyzer

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Biochemistry Analyzer
Certification: CE, FDA, ISO13485
Group: Neonatal, Child and Adult
Sample Consumption: Anticoagulant Whole Blood <=9.6UL
Communication: RS-232c Serial Port
Customization:

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
WHY6280
Print Mode
Internal High-Speed Thermal Printer
Display
TFT LCD (Touch Screen Is Optional)
Input Mode
Mouse and Keyboard (Standard)
Prediluted Capillary Blood
<=20UL
Throughpu
>=60 Samples / H
Name
Hematology Analyzer
Transport Package
Carton
Specification
ISO, CE
Trademark
Poweam
Origin
China
HS Code
90278099
Production Capacity
800PCS/Month

Product Description

WHY6280 (60 tests) 3 parts automatic hematology analyzer

3-Part Diff. Hematology Analyzer (WHY6280) parameter:
Portable Full Automatic Hematology Analyzer WHY6280 parameter information:
25 Parameters: WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH,
MCHC, PLT, PCT,RDW-CV, RDW-SD, MPV, PDW, P-LCR and Histograms for WBC, RBC and PLT etc
Working Principal: Electronic impedance, SFT method for hemoglobin
Throughput: ≥ 60 samples / H
Analysis Mode: Optional venous blood, anticoagulant blood and prediluted blood
Sample Consumption: Anticoagulant whole blood ≤ 9.6μL,
Anticoagulant capillary blood ≤ 9.6μL,
Prediluted capillary blood ≤ 20μL,
(the sample consumption above are for repeating two times testing and avoiding second sampling)

Alarm: Automatic system diagnosis, self testing, fault and reagent shortage alarm
Automated Maintenance: Wash automatically during power on and power off, reducing the blockage rate
Standby Protection: 24 hours switch on, sleep and wake up automatically.
Storage: Large quantity test results storage, at least 400, 000 test results with comprehensive information. Extended SD memory supported.
Control Mode: Quality control mode of L-J, X-B and X-r. Westguard quality control regulation
Calibration Mode: Manual and automatic calibration. Fresh blood calibration is available.
Reference Value Setting: The appropriate reference value range could be automatically selected according to the inputted age and
Sex including children, adults and the aged.
Display: TFT LCD (Touch Screen is optional)
Bar-code reader is optional
Input Mode: Mouse and keyboard (standard). Optional bar code reader and touch screen
Print Mode: Internal high-speed thermal printer. External printer is optional.
Report Format: More than 8 kinds
Dimension: 340mm× 240mm× 320mm
Reagents System: POWEAM reagents OR Open systems are optional
Connection Port: USB, RS-232, network interface, LPT
GW:: 12Kg
 
25 Parameters WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV,
MCH, MCHC, PLT, PCT,RDW-CV, RDW-SD, MPV, PDW, P-LCR and Histograms 
for WBC, RBC and PLT etc
Working Principal Electronic impedance, SFT method for hemoglobin
Throughput ≥ 60 samples / H
Analysis Mode Optional venous blood, anticoagulant blood and prediluted blood
Sample Consumption Anticoagulant whole blood ≤ 9.6μL,
Prediluted capillary blood ≤ 20μL,
Anticoagulant capillary blood ≤ 9.6μL,
Alarm Automatic system diagnosis, self testing, fault and reagent shortage alarm
Automated Maintenance Wash automatically during power on and power off, reducing the blockage rate
Standby Protection  24 hours switch on, sleep and wake up automatically.
Storage Large quantity test results storage, at least 400, 000 test results with comprehensive 
information. Extended SD memory supported.
Control Mode Quality control mode of L-J, X-B and X-r. Westguard quality control regulation
Calibration Mode Manual and automatic calibration. Fresh blood calibration is available.
Reference Value Setting The appropriate reference value range could be automatically selected according to 
the inputted age and Sex including children, adults and the aged.
Display TFT LCD (Touch Screen is optional) Bar-code reader is optional
Input Mode Mouse and keyboard (standard). Optional bar code reader and touch screen
Print Mode Internal high-speed thermal printer. External printer is optional.
Report Format More than 8 kinds
Dimension 340mm× 240mm× 320mm
Reagents System POWEAM reagents OR Open systems are optional
Connection Port USB, RS-232, network interface, LPT
GW 12Kg


 