Ce Approved Hospital ICU Ault Pediatric Neonatal CPAP Bipap Ventilator (H-100D1)

Product Details
Customization: Available
Type: Ventilator
Used for: Adult, Pediatric and Neonatal
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 13485, FSC
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
H-100D1
Input
Touch Screen
Kind
Surgical ICU Equipment
Group
Adult Neonatal and Pediatric
LCD Display
with LCD Display
Certification
Ce, FDA, ISO13485
Display
12-15 Inch LED
Ventilation Mode
Pcv, Psv, Simv, Vcv, CPAP, Bipap etc
Certificates
ISO, Ce, FDA USA
Transport Package
Carton
Specification
CE, FDA USA, ISO
Trademark
Poweam
Origin
China and UK
HS Code
90192000
Production Capacity
500PCS/Month

Product Description

Poweam H-100D1 ventilator suitable for adult pediatric and neonatal.Ventilation mode including PCV,PSV,SIMV+PSV,VCV,CPAP,SIMV, BIPAP,APRV,O2 remedy and manu.
It electrical controlled, gas driven, and time-switch synchronous,with 12-15inch LED display,touch screen input.
 
H-100D1 has the following modes available:
(a) Pressure Control
(b) Volume Control
(c) Spontaneous .
(d) Sigh and Manual Breaths
have servo controlled variable Bias Flow which shuts off totally during patient  exhalation.
Pressure support ventilation  available in volume control, pressure control and spontaneous  modes.
be capable of automatically adjusting the flow waveform rise time  (slope).
have facility to proximally monitor and display the airway pressure and have the facility for distal 
triggering to monitor the patient effort at the Carina.
have the following controls/ settings on the front panel:-
(a)FiO2 0.21 to 1.0
(b)Flow 1 to 100 lpm
(c) Inspiratory Time 0.1 to 3.0 sec.
(d)Tidal Volume 10 ml to 2000 ml.
(e)Inspiratory Pause 0, 10, 20 and 30% of I.T
(f) Respiratory Rate 1 to 100 bpm.
(g) Pressure Control 0 to 75 cm H2O
(h) Pressure Support 0 to 60 cm H2O
(j) PEEP/CPAP 0 to 45 cm H2O
(k) Bias Flow 0 to 30 lpm.
(l) Sensitivity/ Trigger 0 to -5 cm H2O
(m) Maximum Inverse I:E 3:1
(n) Pneumatic Pressure Relief 0 to 120 cm H2O
(o) SIGH 1.5 x Insp. Time Operator Controlled (volume or Pressure Breath)
monitor the following parameter:
(a) Inspiratory Tidal Volume (b) Set Tidal Volume
(c) Inspiratory Minute Volume (d) Respiratory Rate (total)
(e) Peak airway pressure (PIP), Mean airway pressure (MAP) and Baseline Pressure
(PEEP/CPAP)
(f) Inspiratory Peak Flow
have Apnoea backup ventilation available as standard  feature.
have the facility for non-invasive positive pressure ventilation and mask  ventilation.
have a backlit digital manometer for the monitoring of airway pressures  proximally
have a built in Nebulizer to enable the delivery of medication without dis-intubating.
have the following Audio-Visual Alarms:-
(a) High and Low pressure (b) High and Low Minute Volume
(c) I.T too long (d) Ventilator inoperative
have the following audible alarms:-
(a) Gas supply source failure (c) Power Failure
(b) Power Down (d) Proximal Line Disconnect
The critical components like the pressure sensors the flow sensors and the micro processors 
provided in duplicate inside 
the ventilator for safety and reliability.
The ventilator have the facility for independent lung ventilation.
have auto zero function.
The ventilator supplied with a standalone  fisher and paykel humidifier with adult chamber and one 
set adult breathing circuit.
The ventilator system include a standalone Graphic monitor. This have the additional capability of
 being connected to a ventilator already in use in the department. The Graphics monitor monitor all 
parameters proximally (at the patient airway). have the following facilities:-
(i) use autoclavable, reusable flow sensors which are connected at the patient  airway.
(ii) have graphical display of wave forms and loops:-
(iii) monitor and display the following :-
(a) Tidal Volume (e) Oxygen Concentrator (FiO2)
(b) Minute Volume (f) Respiratory Rate
(c) ET-Tube Leakage (g) Peak, Mean and Base Pressures
(d) PEEP
(iv) have interface facility :-
(a) 1 Parallel for Printer (c) 1 Ventilator Connection Port
(b) 1 Serial Interface for PC

Option:
ETCO2,
Air compressor