Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Tech Parameter of patient monitor :
Displayer:8.4" color TFT LCD screen with maximum 7waveform display .
Adjusting of lightness continuously make patient more comfortable in midnight
Battery: Rechargeable high-energy built-in battery
Advanced streamline outline design, portable, compact, lightweight
Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese,French, Arabic, Russian, etc.
Easy operation with user friendly menu structure design and rotary dial
Against electrosurgical interference and defibrillation and no need to disconnect the monitor from
the patient in process of defibrillating.
WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
Optional built-in wireless networking function
Support external printer to record graph and trend
Intelligent audio and visual comprehensive alarm
Suitable for use in physicians' offices, clinics, outpatient surgical centers, extended care facilities
and other patient care areas, which of require affordable monitoring
Standard configuration: ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation.
Optional configuration: Wireless connection, Recorder and, 2-IBP
When the parameter value activated alarm, they will be shown in 3 different colors.
(Red, Yellow and White)
Technical Parameter of patient monitor machine
Temperature (surface and rectal)
Measurement range: 25.0 - 45.0°C
Response time: ≤ 3 min
Accuracy: ± 0.1 °C
Resolution: 0.1 °C
ECG | Input | 5 wires ECG cable |
Lead section | I,II,III/ aVR, aVL, aVF/ V | |
Gain(mm/mV) | 1/4, 1/2, 1, 2, 4 | |
Frequency response | Diagnosis 0.05 - 100Hz Monitor 0.5 - 40 Hz Surgery 1.0 - 25 Hz |
|
Sweep speed(mm/sec) | 12.5, 25, 50 | |
Heart rate range | 30-254 BPM | |
Heart rate accuracy | ± 1 % | |
ST segment deviation analysis | -0.8-+0.8mV | |
ST accuracy | ±0.02mv | |
Respiration Rate(RA-LL impedance and nasal cavity) | ||
Measurement range | 0 - 120 BPM (adult) | |
Accuracy | ± 1 BPM or 5 % | |
Resolution | 1 BPM | |
Environment Temperature | Operation 0.5 - 40°C, Storage -20 - 50 °C |
|
Relative humidity | ≤ 80% | |
Pulse Rate | SPO2 measurement range | 0 - 100 % |
Resolution | 1 % | |
Pulse measurement range | 30- 254BPM | |
Accuracy | ± 2 % | |
Resolution | 1 BPM | |
NIBP (Non-invasive blood pressure) |
Measurement type | adult, pediatric, neonatal |
Measurement range | Systolic 4.0 - 37.0 kPa Diastolic 1.3 - 33.0 kPa Mean 2.6 - 35.0 kPa |
|
Accuracy | ± 0.4 kPa or 5 % | |
Resolution | 0.1 kPa | |
Protection | over pressure | |
IBP(Invasive blood pressure) (with venous punch) (Option) |
Measurement range | -1.3~40kPa (-10~300mmHg) |
Channel | 2 channel | |
Transducer sensitivity | 5MV/V/mmHg | |
Unit display | KPa or mmHg selectable | |
Power requirements | Input | 98~260 V AC, 50/60Hz |
Consumption | ≤ 80VA |