Ce ISO Approved Hospital Nicu, ICU Ventilator with Air Compressor (H-100C)

Product Details
Customization: Available
Type: Ventilator
Ventilation Mode: Ippv, Sippv, Simv, Peep, Manual, Sigh (Imv, Vcv
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Address
No. 18 Fenghua Road, Yuhua Economic Development Zone, Nanjing City, Jiangsu Province, ...
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, CIP, CPT, Others
Terms of Payment
LC, T/T, D/P, Western Union, Small-amount payment
  • Ce ISO Approved Hospital Nicu, ICU Ventilator with Air Compressor (H-100C)
  • Ce ISO Approved Hospital Nicu, ICU Ventilator with Air Compressor (H-100C)
  • Ce ISO Approved Hospital Nicu, ICU Ventilator with Air Compressor (H-100C)
  • Ce ISO Approved Hospital Nicu, ICU Ventilator with Air Compressor (H-100C)
  • Ce ISO Approved Hospital Nicu, ICU Ventilator with Air Compressor (H-100C)
  • Ce ISO Approved Hospital Nicu, ICU Ventilator with Air Compressor (H-100C)
Find Similar Products

Basic Info.

Model NO.
H-100C
Power
AC /DC
Source
Nitrous Oxide
Sigh Inspiratory Time
1.5 Times
LCD Display
with LCD Display
Anesthesia
Closed Circuit
Kind
Surgical
Oxygen Concentration
21%-100%
Tidal Volume
20~2000ml
Simv Rate
1~20bpm
Certification
CE, ISO13485
Group
Adult, Pediatric, Neonatal
Pressure Range
1.0~6.0 Kpa
Low Limit Setting Range
0.2~5.0 Kpa
Display
10.4"Color LCD Display
Transport Package
Wooden Case
Specification
ISO, CE
Trademark
Poweam
Origin
China
HS Code
90189070
Production Capacity
1000PCS/Month

Product Description

vENTILATOR 
10.4" LCD Display,
Parameters for ventilation monitoring: ventilation volume, tidal volume, SIMV rate, IPPV rate.
total respiratory rate, peak pressure of airway, I/E, flow rate - time waveform
Display 10.4" LCD display
Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH (IMV, VCV, PCV) 
Tidal volume 20~2000ml
Rate 1~99bpm
SIMV rate 1~20bpm
I:E 2:1~1:8
Inspiratory trigger pressure  -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressure range  1.0~6.0 kPa
SIGH inspiratory time 1.5 times
Parameters for ventilation monitoring Ventilation volume, tidal volume, SIMV rate, IPPV rate,
 total respiratory rate, peak pressure of airway, I/E, 
flow rate - time waveform, pressure - time waveform, 
inspiratory trigger pressure ,PEEP, Inspiratory platform
Oxygen Concentration 21%-100%
Oxygen Concentration alarm upper limit setting range 21%~100%
low limit setting range   10%~80%
Airway pressure alarm upper limit setting range 0.3~6.0 kPa
low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustained high-pressure alarm > 2.5 kPa
Suffocation alarm no tidal volume input for 15 seconds
Power alarm Yes
Power AC /DC
CO2, ECG  monitoring function optional