Adjust occlusion detection pressure
Adjust KVO rate
Calculation mode,Gradient mode
ntelligent pressure test
Preset maximum value of flow rate
Preset system time
Safety lock for PURGE/BOLUS
Standby function
Preset occlusion detection pressure level (three levels)
Preset Volume To Be Infused
Audible and visual alarm (volume adjustable)
RS232 interface
History data memory
Safety lock for flow rate adjust
Tube heating function
Bolus release
Inquiry of total infused volume
Power indicator
Vehicle Power
Double CPU
Conventional model |
15 d/ml infusion set 0.0ml/h~1200ml/h 20 d/ml infusion set 0.0ml/h~1200ml/h 60 d/ml infusion set 0.0ml/h~300ml/h Note:minimum resolution of setting flow rate is 0.1mL/h when rate is above 1000mL/h, the Resolution is 1mL/h. |
||
Drip Mode |
15 d/ml infusion set 0 d/min~300 d/min 20 d/ml infusion set 0 d/min~400 d/min 60 d/ml infusion set 0 d/min~300 d/min Note:The minimum resolution dripping speed Settings 1d/min. |
||
Accuracy |
≤±3%(Note:Under the condition of the benchmark test, using high elastic silicone iv path accuracy after calibration and commissioning.) |
||
Bubble Detector |
Ultrasonic detection method:Bubble above 25ul is detected |
||
Total Infusion Volume |
0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h) |
||
Volume Limit |
0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h) |
||
Occlusion |
(H):800±200mmHg (106.7±26.7kPa) (C):500±100mmHg (66.7±13.3kPa) (L):300±100mmHg (40.7±13.3kPa) |
||
History Record |
These serial products can maximally store 4500 pieces of history records. The record includes the following information: Date, flow rate, alarm data, total volume delivered, occlusion pressure and syringe brand and serial number. |
||
Alarm |
Near empty alarm,Empty alarm,Door open alarm, Bubble alarm,limited value reached alarm, AC power failure,Low battery alarm,Battery empty alarm,Remind alarm,Flow regulator or inlet valve closed alarm (optional) |
||
Power |
Supply Voltage:AC100V~240V(±10%),Power Frequency: 50Hz-60Hz Built-in Battery:DC15V Ni-MH battery(It can be replaced by lithium ion battery pack necessary.) Working time of battery:In case the battery is fully charged, the continuous working time can be up to 6 hours at the speed of 25ml/h. Maximum power:30VA;Note:Before the first use of this product, the battery must be charged while being shut down for more than 12 hours. |
||
Working Environment |
Temperature:+5ºC-+40ºC Relative humidity:20%-90% Environmental pressure:860hPa-1060hPa |
||
Transport And Storage Environment |
Temperature:-20ºC~+55ºC; Atmosphere Pressure:500hPa~1060hPa. products should be stored in the relative humidity in the range of 10% ~ 93%, no corrosion gas indoor and ventilated. |
||
Electric Safety Classification |
Class I, CF type,Built-in battery,Continuous operation equipment |
||
Water Proof Level |
IPX4 |
||
Net Weight |
2.2kg(include fastener) |
||
Dimension |
320mm(W)×132mm(H)×138mm(D) |