Medical Zoll Aed Plus Defibrillator

Product Details
Customization: Available
Classification: Biochemical Apparatus
Type: Defibrillator
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 13485, FSC
OEM/ODM Availability
Yes
  • Medical Zoll Aed Plus Defibrillator
  • Medical Zoll Aed Plus Defibrillator
  • Medical Zoll Aed Plus Defibrillator
  • Medical Zoll Aed Plus Defibrillator
  • Medical Zoll Aed Plus Defibrillator
  • Medical Zoll Aed Plus Defibrillator
Find Similar Products

Basic Info.

Model NO.
DM-7000
Group
Adult
External Defibrillator
Defibrillator
Transport Package
1 PCS/Carton
Trademark
Poweam
Origin
Nanjing
HS Code
90181930

Product Description

zoll aed plus defibrillator

Poweam DM7000 AED biophasic defibrillator with monitor function can meet all of your clinical request from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS).
 
Specifications for defibrillator
Display
Display Type  7 inch high resolution LCD display
Sweep Speed  25mm/sec
Information  HR, Lead/Pads, On/Off Alarm , SpO2,
 AED Functions and Prompts,
 Alarm Selection and Limits, Delivered Energy.
Below is feature
Waveform  Biphasic
Charge Time  Less than 7 seconds with a new fully charged battery.
Energy Display  Monitor display indicates both selected and delivered energy.
Charge Prompt Type  Voice and visual prompts.
Electrode Impedance Measurement Range  0-250 ohms.
ECG Monitoring for Defibrillator
Patient Connection  5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection  Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size  0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate  20-300BPM.
Heart Rate Alarm  On/Off displayed on monitor, user-selectable.
Smart Alarms  Beeper/voice prompts indicate shockable rhythm.
SpO2 Module
Measurement Range  30~100%, 
± 2% between 80%~90%,
 others ± 5%
Alarm Range  User set high limit and low limit.
Alarm Accuracy  ± 10% within setting values.
Alarm time Accuracy  Less than 12 sec.
Recorder
Paper  50mm thermal.
Speed  12.5mm/sec, 25mm/sec, 50mm/sec. 
 User-selectable 6-second delay.
Printing Method  High-resolution, thermal print head.
Print-out Modes  Manual or automatic, user-configurable.
On/Off Control  Front panel and paddle.
Automatic Function  9-seconds recording initiated by alarm activation or 
defibrillator charge or defibrillator discharge.
Battary
Type  Rechargeable, Ni-MH battery, 12V.
Operating Time  For a new, fully charged 
battery 60 defibrillator discharges at maximum energy, 
or 3 hours minimum of continuous ECG monitoring.
 Additional parameters will effect operating time with different functions.
AED Mode
AED Function  Auto analyze and charge X3 with programmable auto energy level selection, 
 screen prompts, and voice prompts.
Shockable Rhythms  Ventricular fibrillation with amplitude >=200UV, 
 ventricular tachycardia with rates >=140bpm,
 and QRS complex wave duration >=140ms.
Charge Control  Control on device front panel, press key on paddle.
Prompts  Voice and visual prompts.
Manual Mode
Energy Selection  Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
Synchronized Mode  Synchronizes defibrillator pulse to patient's R-wave. 
"SYNC" message displayed on monitor
Model DM7000
Brief Introduction biophasic AED defibrillator,7" LCD
Patient Monitor
ECG,HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts,
Alarm Selection and Limits, Delivered Energy.

Medical Zoll Aed Plus Defibrillator

Medical Zoll Aed Plus Defibrillator