Below is more information:
10.4'' large color LCD,
Dual test units,
No interference of contamination, no drifting of test units,
Intelligent pulse system for data analysis,
Up to 60 samples/hour,
High reliability & Safety (The most advanced technology and structure),
Adopting the most advanced binuclear embedded digital circuit system makes the analyticalability great and stable,
Separate test units WBC and RBC makes the test results more accurate and less cross-contamination,
Adopting CPLD technology in data processing, free from the interference of electromagnetic signal,
Economical and Durable,
Long life of the machine, all accessories with high performance,
Classic design of highly reliable fluid pipe structure,
Long-term stability, accurate and reliable clinical test results is the core of WHY6380,
Easy operation,
Easy operation interface,
Dual test units, fast and convenient,
Module design, fast maintenance,
Technical data:
Principle: electrical impedance for counting and SFT method for hemoglobin,
Test parameters: 3 part differentials of WBC,
23 parameters(including WBC, RBC, PLT color histogram)
Sample quantity: 9ul venous blood, 20ul pre-dilution blood
Sample Pre-dilution:
Internal diluter, add 1 ml diluent automatically by the needle;
no need to add diluent manually, to avoid error and make the operation more convenient,
Standard Working model: dual-channel testing,
Aperture: WBC 80um RBC/PLT 50um
Throughput: Automatic sampling, 60 samples per hour,
Results storage: Storage of 10,000 patients' results (including histogram), It is more convenient to manage and review historical data.
Reference value setting: For general use, male, female, children, newborns.
Calibration: Manual and automatic calibration.
QC: comprehensive QC program, forming and printing the histogram automatically.
Performance index: precision (CV) liner range
HGB≤1.5% 0~300g/L
WBC≤1.5% 0.00~99.9X109/L
PLT≤4.0% 0~999X109/L
RBC≤1.5% 0.00~99.9X1012/L
MCV≤0.3% 40~150FL
Boot check: self check for hardware, alarm for disorder
Principle |
electrical impedance for counting and SFT method for hemoglobin, |
Test parameters |
3 part differentials of WBC,23 parameters(including WBC, RBC, PLT color histogram) |
Sample quantity |
9ul venous blood, 20ul pre-dilution blood |
Sample Pre-dilution |
Internal diluter, add 1 ml diluent automatically by the needle,no need to add diluent manually, to avoid error and make the operation more convenient |
Standard Working model |
dual-channel testing, |
Aperture |
WBC 80um RBC/PLT 50um |
Throughput |
Automatic sampling, 60 samples per hour, |
Results storage |
Storage of 10,000 patients' results (including histogram), It is more convenient to manage and review historical data. |
Reference value setting |
For general use, male, female, children, newborns. |
Calibration |
Manual and automatic calibration. |
QC |
comprehensive QC program, forming and printing the histogram automatically. |
Performance index |
precision (CV) liner range |
WBC≤1.5% 0.00~99.9X109/L |
RBC≤1.5% 0.00~99.9X1012/L |
HGB≤1.5% 0~300g/L |
PLT≤4.0% 0~999X109/L |
MCV≤0.3% 40~150FL |