Jiangsu, China
Business Type:
Manufacturer/Factory
Management System Certification:
ISO 9001, ISO 9000, ISO 13485, FSC
OEM/ODM Availability:
Yes
OEM/ODM Service
Sample Available
Overseas Agent / Branch
Spanish Speaker

Hematology Analyser, Haematology Analyzer, Blood Analyzer manufacturer / supplier in China, offering Ce Approval Advanced Clinic Portable Hematology Analyser (6280), High Purity High Quality Hot Sale Price X Ray Film Cassette, Good Quality Medium Speed Blue Medical Intensifying Screen Price and so on.

Gold Member Since 2015
Audited Supplier
Supplier Homepage Products IVD & Clinic Analyzers etc Ce Approval Advanced Clinic Portable Hematology Analyser (6280)

Ce Approval Advanced Clinic Portable Hematology Analyser (6280)

Get Latest Price
Min. Order / Reference FOB Price
50 Pieces US $1,800-3,000/ Piece
Port: Shanghai, China
Production Capacity: 500PCS/Month
Payment Terms: L/C, T/T, Western Union
Classification: Biological Diagnostics
Type: Urine/Hematology Analyzer
Certification: CE, FDA, EEC, MSDS, ISO13485
Group: Neonatal, Child and Adult
Storage: More Than 400,000 Samples
Throughput: >=60 Samples / H

You Might Also Like

Loading...

Basic Info

Model NO.: WHY6280
Analysis Mode: Optional Venous , Anticoagulant and Prediluted
Sample Consumption: Anticoagulant Whole Blood <=9.6UL
Prediluted Capillary Blood: <=20UL
Display: TFT LCD (Touch Screen Is Optional)
Print Mode: Internal High-Speed Thermal Printer
Input Mode: Mouse and Keyboard (Standard)
Power Supply: AC 110-230V.50/60Hz
Trademark: Poweam
Transport Package: Carton
Specification: ISO, CE, FDA
Origin: China
HS Code: 90278099

Product Description

Below is tech parameter:
Portable Full Automatic Hematology Analyzer WHY6280 parameter information:
25 Parameters: WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH,
MCHC, PLT, PCT,RDW-CV, RDW-SD, MPV, PDW, P-LCR and Histograms for WBC, RBC and PLT etc
Working Principal: Electronic impedance, SFT method for hemoglobin
Throughput: ≥ 60 samples / H
Analysis Mode: Optional venous blood, anticoagulant blood and prediluted blood
Sample Consumption: Anticoagulant whole blood ≤ 9.6μL,
Prediluted capillary blood ≤ 20μL,
Anticoagulant capillary blood ≤ 9.6μL,
(the sample consumption above are for repeating two times testing and avoiding second sampling)

Alarm: Automatic system diagnosis, self testing, fault and reagent shortage alarm
Automated Maintenance: Wash automatically during power on and power off, reducing the blockage rate
Standby Protection: 24 hours switch on, sleep and wake up automatically.
Storage: Large quantity test results storage, at least 400, 000 test results with comprehensive information. Extended SD memory supported.
Control Mode: Quality control mode of L-J, X-B and X-r. Westguard quality control regulation
Calibration Mode: Manual and automatic calibration. Fresh blood calibration is available.
Reference Value Setting: The appropriate reference value range could be automatically selected according to the inputted age and
Sex including children, adults and the aged.
Display: TFT LCD (Touch Screen is optional)
Bar-code reader is optional
Input Mode: Mouse and keyboard (standard). Optional bar code reader and touch screen
Print Mode: Internal high-speed thermal printer. External printer is optional.
Report Format: More than 8 kinds
Dimension: 340mm× 240mm× 320mm
Reagents System: POWEAM reagents OR Open systems are optional
Connection Port: USB, RS-232, network interface, LPT
GW:: 12Kg
 
25 ParametersWBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV,
MCH, MCHC, PLT, PCT,RDW-CV, RDW-SD, MPV, PDW, P-LCR and Histograms 
for WBC, RBC and PLT etc
Working PrincipalElectronic impedance, SFT method for hemoglobin
Throughput≥ 60 samples / Hour
Analysis ModeOptional venous blood, anticoagulant blood and prediluted blood
Sample ConsumptionAnticoagulant whole blood ≤ 9.6μL,
Prediluted capillary blood ≤ 20μL,
Anticoagulant capillary blood ≤ 9.6μL,
AlarmAutomatic system diagnosis, self testing, fault and reagent shortage alarm
Automated MaintenanceWash automatically during power on and power off, reducing the blockage rate
Standby Protection 24 hours switch on, sleep and wake up automatically.
StorageLarge quantity test results storage, at least 400, 000 test results with comprehensive 
information. Extended SD memory supported.
Control ModeQuality control mode of L-J, X-B and X-r. Westguard quality control regulation
Calibration ModeManual and automatic calibration. Fresh blood calibration is available.
Reference Value SettingThe appropriate reference value range could be automatically selected according to 
the inputted age and Sex including children, adults and the aged.
DisplayTFT LCD (Touch Screen is optional) Bar-code reader is optional
Input ModeMouse and keyboard (standard). Optional bar code reader and touch screen
Print ModeInternal high-speed thermal printer. External printer is optional.
Report FormatMore than 8 kinds
Dimension340mm× 240mm× 320mm
Reagents SystemPOWEAM reagents OR Open systems are optional
Connection PortUSB, RS-232, network interface, LPT
GW12Kg
Ce Approval Advanced Clinic Portable Hematology Analyser (6280)
Ce Approval Advanced Clinic Portable Hematology Analyser (6280)
Ce Approval Advanced Clinic Portable Hematology Analyser (6280)

Send your message to this supplier

*From:
*To:
avatar Ms. Ann
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now