First Aid with Aed Manual Mode SpO2, ECG Defibrillator

Product Details
Customization: Available
Classification: Biochemical Apparatus
Type: Defibrillator
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 13485, FSC
OEM/ODM Availability
Yes
  • First Aid with Aed Manual Mode SpO2, ECG Defibrillator
  • First Aid with Aed Manual Mode SpO2, ECG Defibrillator
  • First Aid with Aed Manual Mode SpO2, ECG Defibrillator
  • First Aid with Aed Manual Mode SpO2, ECG Defibrillator
  • First Aid with Aed Manual Mode SpO2, ECG Defibrillator
  • First Aid with Aed Manual Mode SpO2, ECG Defibrillator
Find Similar Products

Basic Info.

Model NO.
DM-7000
Group
Adult
Transport Package
1 PCS/Carton
Trademark
Poweam
Origin
Nanjing
HS Code
90181930

Product Description

Defibrillator in Hospital

Poweam DM7000 AED biophasic defibrillator with monitor function can meet all of your clinical request from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS).

Specifications of defibrillator 

Display
Sweep Speed: 25mm/sec

Display Type: 7 inch high resolution LCD display,
Information: HR, Lead/Pads, On/Off Alarm , SpO2, AED Functions and Prompts, Alarm Selection
and Limits, Delivered Energy.

Below is feature:
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.

ECG Monitoring
Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockable rhythm.


SpO2 Module
Measurement Range: 30~100%, ± 2% between 80%~90%, others ± 5%
Alarm Range: User set high limit and low limit.
Alarm Accuracy: ± 10% within setting values.
Alarm time Accuracy: Less than 12 sec.

Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal print head.
Print-out Modes: Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

Battary
Type: Rechargeable, Ni-MH battery, 12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.

AED Mode
AED Function: Auto analyze and charge X3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200UV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel, press key on paddle.
Prompts: Voice and visual prompts.

Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor
 
Model DM7000
Brief Introduction biophasic AED defibrillator,7" LCD
Patient Monitor
ECG,HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts,
Alarm Selection and Limits, Delivered Energy.

First Aid with Aed Manual Mode SpO2, ECG DefibrillatorFirst Aid with Aed Manual Mode SpO2, ECG Defibrillator